SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.7
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
Note.4
OVER VOLTAGE
OVER TEMPERATURE
12V
LPF-40D-12 LPF-40D-15 LPF-40D-20 LPF-40D-24 LPF-40D-30 LPF-40D-36 LPF-40D-42 LPF-40D-48 LPF-40D-54
7.2 ~12V
15V
9 ~ 15V
20V
12 ~ 20V
24V
14.4 ~ 24V
30V
18 ~ 30V
36V
21.6 ~ 36V
48V
28.8 ~ 48V
3.34A 2.67A 2A 1.67A
1.34A
1.12A
0.84A
40.08W 40.08W 40W 40.08W 40.2W
40.32W
40.32W
150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
250mVp-p
250mVp-p
±4.0% ±4.0% ±4.0% ±4.0% ±4.0%
±4.0%
±4.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±2.0% ±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5%
1000ms, 80ms / 115VAC at full load 1000ms, 80ms / 230VAC
16ms/230VAC 16ms/115VAC at full load
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
84%
85%
86%
87%
88%
88%
89%
<0.75mA / 240VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
394.9K hrs min. MIL-HDBK-217F (25 )
162.5*43*32mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
0.45Kg; 32pcs/15.4Kg/0.93CUFT
Protection type : Shut down and latch off o/p voltage, re-power on to recover
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed.
54V
32.4 ~ 54V
0.76A
41.04W
350mVp-p
±4.0%
±0.5%
±0.5%
42V
25.2 ~ 42V
0.96A
40.32W
250mVp-p
±4.0%
±0.5%
±0.5%
88.5% 89%
15 ~ 17V 17.5 ~ 21V
23 ~ 27V
28 ~ 35V
34 ~ 40V
41 ~ 49V 54 ~ 63V
0.6A / 115VAC 0.3A / 230VAC 0.25A / 277VAC
46 ~ 54V 59 ~ 66V
File Name:LPF-40D-SPEC 2014-01-15
40W Single Output Switching Power Supply
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 89%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Fully isolated plastic case
Fully encapsulated with IP67 level (Note.6)
Class power unit, no FG
Class 2 power unit
dimming function (1~10Vdc or PWM signal or resistance)Built-in 3 in 1
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty
Features :
LPF-40D series
ISOLATION RESISTANCE
CONSTANT CURRENT REGION
Note.4
SAFETY STANDARDS Note.6
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMC IMMUNITY
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A
EMC EMISSION
FMM
110
UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP67, J61347-1, J61347-2-13
approved ; design refer to UL60950-1, TUV EN60950-1
COLD START 50A(t =210 s measured at 50% I ) at 230VACwidth peak
μ
IP67
SELV
( for 48V,54V only) ( except for 48V,54V )
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - LPF-40D series

SPECIFICATIONMODELDC VOLTAGERATED CURRENTRATED POWEROUTPUTLINE REGULATIONLOAD REGULATIONSETUP, RISE TIMENote.7HOLD UP TIME (Typ.)VOLTAGE RANGENote.5FR

Page 2

Mechanical SpecificationCase No.LPF-60B Unit:mmLOAD (%)20406080100INPUT VOLTAGE (V) 60Hz90 100 125 135 145 155 165 175 180 200 230 3051009080

Page 3

70717273747576777879808182838485868788899091929310% 20% 30% 40% 50% 60% 70% 80% 90% 100%277VAC230VAC115VAC0.840.850.860.870.880.890.90.910.920.930.940

Page 4

Dimming connection diagram for turning the lighting fixture ON/OFF :Using a switch and relay can turn ON/OFF the lighting fixture.※Using the built-in

Commentaires sur ces manuels

Pas de commentaire